2 5.2 troubleshooting guides – Frymaster Gas Rethermalizers FBKR18 Series User Manual

Page 29

Advertising
background image

5-2

5.2

Troubleshooting Guides

COOKPOT DID NOT

FILL WHEN UNIT WAS

TURNED ON. WATER

SUPPLY TO UNIT

VERIFIED TO BE ON.

Did anything

appear in CM III display

when unit was

turned on?

Computer is not functioning.

Probable causes are failed 12V

transformer, failed interface

board, or failed computer.

Open control panel

by removing screws

in upper corners.

Is WATER

LED on interface board

illuminated?

Use bottle brush to

clean water level

sensors.

Did LED

illuminate?

Did unit

begin to fill?

Probable causes are a failed

interface board or a failed

high-level water sensor.

Problem resolved.

Call FASC.

Probable causes are a failed

water solenoid or a failed

interface board.

Yes

No

No

Yes

Yes

No

Yes

No

Advertising
This manual is related to the following products: