6-11

If popping is consistent during all hours of operation, the most likely cause is an insufficient air
supply. Check for “negative pressure” conditions in the kitchen area. If air is flowing into the
kitchen area, this indicates that more air is being exhausted than is being replenished, and the
burners may be starved for air.

If the rethermalizer’s gas and air supplies are okay, the problem is most likely with one of the
electrical components. Examine the ignition module and computer for signs of melting/distortion
and/or discoloration due to excessive heat build-up in the equipment. (This condition usually
indicates improper flue performance.) A melted or distorted ignition module is automatically
suspect and should be replaced, but unless the condition causing excessive heat is corrected, the
problem is likely to recur.

Verify that the ignition wire is tightly connected at both ends and free of obvious signs of damage.
Again, if damage is due to excessive heat in the equipment, that problem must also be corrected.
Check for proper operation by disconnecting the wire from the ignitor, inserting the tip of a screw
driver into the terminal, and holding it near the frame of the unit as the power switch is placed in the
on position. A strong blue spark should be generated for at least 4 seconds.

DANGER

Make sure the insulated handle of the screwdriver is held and not the blade. The
sparking charge is approximately 25,000 volts.

Examine the ignitor for any signs of cracking. A cracked ignitor must be replaced.

If all other causes have been ruled out, examine the burner tiles for any signs of cracking. If found,
the burner must be replaced.

Fluctuating flame intensity is normally caused by either improper or fluctuating incoming gas
pressure, but may also be the result of variations in the kitchen atmosphere. Verify incoming gas
pressure in the same way as for popping discussed in the preceding paragraphs. Variations in the
kitchen atmosphere are usually caused by air conditioning and/or ventilation units starting and
stopping during the day. As they start and stop, the pressure in the kitchen may change from
positive or neutral to negative, or vice versa. They may also cause changes in airflow patterns that
may affect flame intensity.

Dark spots on the burner tiles are the result of an improper air/gas mixture. Adjust the combustion
air blower to reduce the amount of air in the mixture to correct this problem.

Flames shooting out of the flue are usually an indication of negative pressure in the kitchen. Air is
being sucked out of the burner enclosure and the flames are literally following the air. If negative
pressure is not the cause, check for high burner manifold gas pressure in accordance with the
procedures in Chapter 4.

An excessively noisy burner, especially with flames shooting out of the flue, may indicate that the
gas pressure is too high, or it may simply be that the gas valve vent tube is blocked. If the incoming
gas pressure is correct and the vent tube is unobstructed, the gas valve regulator is probably
defective.