www.fmiproducts.com

108794-01G

6

ProduCt sPeCIFICAtIoNs

Figure 2 - Appliance Dimensions

6

7

/

8

"

2

1

/

4

"

7"

7"

Alternate Gas

Supply Inlet

13

1

/

4

"

32

1

/

4

"

* 27

1

/

2

"

29"

* 13

3

/

4

"

14

1

/

2

"

* 20

3

/

8

"

21

1

/

2

"

2

1

/

2

"

8

1

/

4

"

11

3

/

4

"

22

3

/

8

"

For Use

With B-1

Vent Pipe

Only

16

3

/

4

"

7

5

/

8

"

10

5

/

8

"

8

1

/

8

"

10

1

/

2

"

8

3

/

8

"

2

1

/

2

"

8

1

/

4

"

5/8"

34

1

/

2

"

35

3

/

8

"

29

1

/

2

"

18

1

/

4

"

7"

7"

16

3

/

4

"

36

1

/

2

"

* WITH REFRACTORY

DIMENSIONS

HEARTH AREA

GAS RATING - NATURAL

P324E, VP324E

P325E(B), VP325E(B)

Max. Input Rating:

15,000 Btu/Hr

25,000 Btu/Hr

Manifold Pressure:

3.5" WC (.87 kPa)

3.5" WC (.87 kPa)

Minimum Supply Pressure:

4.5" WC (1.12 kPa)

4.5" WC (1.12 kPa)

Maximum Supply Pressure:

10.5" WC (2.66 kPa)

10.5" WC (2.66 kPa)

Orifice Size:

# 49

# 40

GAS RATING - PROPANE/LP

Max. Input Rating:

15,000 Btu/Hr

25,000 Btu/Hr

Manifold Pressure:

10" WC (2.49 kPa)

10" WC (2.49 kPa)

Minimum Supply Pressure:

11" WC (2.74 kPa)

11" WC (2.74 kPa)

Maximum Supply Pressure:

13" WC (3.23 kPa)

13" WC (3.23 kPa)

Orifice Size:

# 56

# 54