Pre-INstAllAtIoN PrePArAtIoN

Continued

FRAMING

1. Frame appliance enclosure as illustrated

in Figures 7 and 8.

Note: If a wall covering is used to line

enclosure, then all measurements must

be from surface of covering.

2. Place appliance into framing and secure.

Note: If appliance is to be raised above

floor level, a platform must be built to

support appliance.

3. Install supply line to appliance using a

1/2" NPT black iron gas line terminating

2

5

/

16

" above bottom of appliance. The gas

line must be installed through the lower

left side access point or alternate access

hole in bottom of appliance (see Figure

16, page 12).

4. Feed flexible gas line through one of three

gas line conduit sleeves and repack insu-

lation to cover any openings. Prepare the

incoming gas line with teflon tape or pipe

joint compound and hook up incoming gas

line to flexible gas line.

Note: If 1/2" NPT black iron pipe does not

mate with fitting at end of flexible gas line,

remove fitting and replace with a 37° flare

3/4"-12, 1/2" NPT (female) fitting.

WARNING: When finishing

appliance, do not overlap com-

bustible material onto the black

front face. Brick, tile or other non-

combustible materials may be

applied to the face provided that

any gap is between the material

used and the face is caulked with

a noncombustible caulking.

Figure 7 - Rough Opening for Installing

in Wall

Figure 8 - Corner Installation Guidelines

16

3

/

4

"

12"

39

3

/

8

"

55

5

/

8

"

34

1

/

2

"

16"

These Dimensions Allow for a 3/4"

Clearance at Sides and Back of Fireplace.

However, 0" Clearance is Permitted

3/4" Clearance Not Required at

Nailing Flanges

VeNtING INstAllAtIoN

16

1

/

8

"

34

3

/

4

"

36

5

/

8

"

A B-type venting system must be connected to

appliance for venting to outside of building.
The following section is provided as a guide

to a standard B-type vent installation.
Standing codes requirements concerning B-

type vent installations may vary within your

state, province or local codes jurisdiction.

Therefore, it is recommended that you check

with your local building codes for specific

requirements or in absence of local codes,

follow Section 7.0 of the current National Fuel

Gas Code ANSI Z223.1/NFPA 54.
This gas appliance must be vented to the

outdoors only and may not be terminated into

an attic space or into a chimney flue servicing

a solid fuel burning appliance.