Pre-installation preparation, Mantel clearances and wall details, Clearances – FMI PFS P324E User Manual

Page 7

Advertising
background image

www.fmiproducts.com

108794-01G

7

Pre-INstAllAtIoN PrePArAtIoN

Figure 3 - Minimum Clearances

(Top View)

0"

0" Clearance

Nailing

Flange

Front Face

Left Side

Surround

Back

Drywall

2 x 4 Stud

Figure 4 - Minimum Clearances

(Front View)

MANTEL CLEARANCES AND WALL

DETAILS

A combustible mantle shelf maybe installed

a maximum 12" (22.90 cm) from the wall.

Figures 5 and 6 show the minimum allow-

able distances from various combustible

mantle components in relation to the fireplace

opening.

Figure 5 - Mantel Clearances - Side View

(Cross Section)

Figure 6 - Side Clearances - Top View

(Cross Section)

*

*

*

*

42" (10.67 cm)
Min. Clearance
from Opening to
Ceiling

0" Clearance

Ceiling

1" (2.5 cm) Min.
Clearance to
"B" Vent's Outer Pipe

Required
Air Spaces
are Indicated
with an "*".

Do Not
Pack with
Insulation or
Any Other
Material

DO NOT BLOCK

OR OBSTRUCT

OPENINGS

0" Clearance
to Wood or
Noncombustible
Flooring

Spacer

3" (7.6 cm)

1

1

/

2

"

(3.8 cm) Max.

8" (20.3 cm)

6" (15.2 cm)

13" (33 cm)

12"

(22.9 cm)

Combustible
Materials

Header

1

1

/

2

" (3.8 cm)

Max.

3" (7.6 cm)

Max.

6" (15.2 cm)

Max.

9"

(22.86 cm)

12"

(30.48 cm)

Outer Surround

Combustible
Material May
Be Used

TOP VIEW

SAFE
ZONE

Perpendicular
Wall

CLEARANCES

Minimum clearances to combustibles are:

• Top of Spacers

0" min.

• Back/Sides of Outer Surround

0" min.

• Drywall to Sides of Front Face

(Nailing Flanges)

0" min.

• “B” Vent Surfaces

1" min.

• Ceiling to Opening

42" min.

• Floor

0" min.

• Perpendicular Wall

See Figure 6

CAUTION: Do not block

required air spaces with insu-

lation or any other material. Do

not obstruct effective opening

of appliance with any type of

facing material.