Remove a dc power supply – Force10 Networks Force10 TeraScale E-Series E1200i User Manual

Page 70

Advertising
background image

70

Removing and Replacing Components

Remove a DC Power Supply

Step

Task

1.

Ensure that the remote power source is in the OFF position and that the PEM status light is off.

• PEM 0 connects to remote power source 0.

• PEM 1 connects to remote power source 1.

2.

Loosen the retaining screw and remove the PEM safety cover.

3.

Switch the Over Current Protector (located on the PEM front panel) to the OFF position.

4.

Loosen the Locking screws.

FN00103lp

S afety

cover

R etaining

s crew

CC-E1200-PWR-DC

-48/-60Vdc
150A, 7200VA

Status

Latch Release

PEM interlock

lever

Over-current protector

Locking screws

Studs

FN00102lp

Advertising