Installing and Maintaining the E1200i System

93

E1200i DC Chassis Physical Design

E1200i DC System Power Requirements

Parameter

Specifications

Height

36.75 inches (93.35 cm)

Width

17.40 inches (44.20 cm)

Depth (without cable management system)

21.25 inches (53.98 cm)

Chassis weight with factory-installed components
(backplane and air filter)

97 pounds (approx.) (44.00 kg)

Weight fully loaded (backplane, air filter, 2 fan trays, 10
SFMs, RPMs, and 14 line cards)

319 pounds (approx.) (144.70 kg)

Mounting

Attached rack mount brackets are factory set for front
mounting in a standard 19-inch rack.

Mounting brackets are adjustable for center and rear
mounting.

Optional brackets are available for front or center
mounting in a 23-inch rack or cabinet.

Rack clearance required

Front: 18 inches

Rear: 20 inches

Thermal Output

Maximum for fully loaded chassis

6850W (23,389 BTU/HR)

Minimum for chassis with one 48-port 1GE line card

1,450W (4,951 BTU/HR)

Parameter

Specifications

Maximum Power Consumption

6,850W

Input Voltage Range

200-240 VAC 50/60 Hz

Maximum Heat Dissipation

6,325W (21,598 BTU/HR)

Maximum Power Supply Input Current

16A per module