Removing and replacing the air filter, Figure 27, Replacing the air filter – Force10 Networks Force10 TeraScale E-Series E1200i User Manual

Page 73

Advertising
background image

Installing and Maintaining the E1200i System

73

Removing and Replacing the Air Filter

A factory-installed air filter (

Figure 27

) is shipped with the E1200i system. The hot-swappable air filter

prevents large particles, debris, and dust from entering and circulating through the system, and ensures
proper air flow through the system. Filters should be inspected monthly and replaced every twelve months
or as required.

To remove and replace the air filter:

Figure 27 Replacing the Air Filter

Warning: An improperly installed air filter will restrict air flow and will generate thermal problems
throughout the chassis. Ensure the air filter is oriented correctly and seated securely in the slot.

Do not operate without a filter for any longer than 30 minutes to avoid card over-temperature conditions.

Step

Task

1.

Pull the air filter straight out of the chassis.

2.

Rotate the replacement filter so that the front handle label is right reading.

3.

Guide the filter firmly into the slot until it stops.