10.13 Controller Area Network (CAN) Timing

Note: CAN is NOT available in the 56F8122 device.

Figure 10-17 Bus Wakeup Detection

10.14 JTAG Timing

Table 10-22 CAN Timing

1

1. Parameters listed are guaranteed by design

Characteristic

Symbol

Min

Max

Unit

See Figure

Baud Rate

BR

CAN

1

Mbps

Bus Wake-up detection

T

WAKEUP

T

IPBUS

µ

s

10-17

Table 10-23 JTAG Timing

Characteristic

Symbol

Min

Max

Unit

See Figure

TCK frequency of operation using

EOnCE

1

1. TCK frequency of operation must be less than 1/8 the processor rate.

f

OP

DC

SYS_CLK/8

MHz

10-18

TCK frequency of operation not

using EOnCE

1

f

OP

DC

SYS_CLK/4

MHz

10-18

TCK clock pulse width

t

PW

50

ns

10-18

TMS, TDI data set-up time

t

DS

5

ns

10-19

TMS, TDI data hold time

t

DH

5

ns

10-19

TCK low to TDO data valid

t

DV

30

ns

10-19

TCK low to TDO tri-state

t

TS

30

ns

10-19

T

WAKEUP

MSCAN_RX

CAN receive

data pin

(Input)

Advertising