3 main menu → timer settings – GE DSR-1000eZ User Manual

Page 33

Advertising
background image

0150-0238A

4-3

Calibur DSR-1000eZ

This teletext alarm detecting feature of the DSR-1000eZ is compatible with the following styles of
Multiplexers:

Kalatel

Philips

Robot

Pelco

Sanyo

Philips REO

ATV

ATV QSP

Vista VLM

QSI 1700

Diebold

Connecting to Dedicated Micros (DM)

When connecting to a Dedicated Micros multiplexer:

It is necessary to connect the alarm output of the Mux to the alarm input of the DSR-1000eZ (as
you would do when connecting the alarm input on standard time-lapse VCR).

It is necessary to configure the Main Menu

→ Alarms → Hardwire Alarm as Enabled.

It is necessary to configure the Main Menu

→ Alarms → Teletext Alarm as Disable.

Alarm Menu

Hardwire Alarm : Enable

Teletext Alarm : Disable

Alarm Buzzer : Enable

[CANCEL]

[OK]

To configure the alarm settings:

1. Use the Shuttle to navigate among the fields.

2. Use the Jog to change the values of the highlighted

fields.

3. To Save the changes and Exit the menu: Use the

Jog to select [OK], then press the Enter button.

--OR--

4. To Exit the menu without making changes: Use the

Jog to select [CANCEL], then press the Enter button.

4.3 Main Menu

→ Timer Settings

DATE

START

STOP

SPD(pps)

QUALITY ON/OFF

31

Sat

Mon-Fri

Sat-Sun

Mon-Sun

--

16:45

07:55

09:56

14:23

02:23

--:--

17:05

08:10

11:05

14:50

03:34

--:--

20

10

60

60

20

--

[OK]

High

Med

Low

High

Med

--

On

Off

On

On

Off

--

This menu allows the user to
program a timed-recorded
event. Use this menu to
specify:

The date, or days on
which the recording
will occur.

The start and stop
time.

The record speed.

The record quality.

Whether the event is
enabled.

EDIT Mode Hit "ENTER" To Toggle EDIT Mode