CHAPTER 5: OVERVIEW

32

EPM 5000 series Advanced Power Meters GE Multilin

5.7: Resetting Hour Readings

MAX/MIN

LIMITS

KVAR

PF

KW
KVA

FREQ

KWH

KVAH

AC VOLTS

AC AMPS

POWER

N

C

B

A

MAX
MIN

A

N

B

N

C

N

A

B

B

C

C

A

LM2

LM1

NEXT

PHASE

VOLTS AMPS POWER

MAX/MIN

LIMITS

KVAR

PF

KW
KVA

FREQ

KWH

KVAH

AC VOLTS

AC AMPS

POWER

N

C

B

A

MAX
MIN

A

N

B

N

C

N

A

B

B

C

C

A

LM2

LM1

NEXT

PHASE

VOLTS AMPS POWER

MAX/MIN

LIMITS

KVAR

PF

KW
KVA

FREQ

KWH

KVAH

AC VOLTS

AC AMPS

POWER

N

C

B

A

MAX
MIN

A

N

B

N

C

N

A

B

B

C

C

A

LM2

LM1

NEXT

PHASE

VOLTS AMPS POWER

MAX/MIN

LIMITS

KVAR

PF

KW
KVA

FREQ

KWH

KVAH

AC VOLTS

AC AMPS

POWER

N

C

B

A

MAX
MIN

A

N

B

N

C

N

A

B

B

C

C

A

LM2

LM1

NEXT

PHASE

VOLTS AMPS POWER

Step 1:

a. Press POWER once.

b. Press PHASE/NEXT

for the desired hour

function.

!

This example uses

KWH function.

Step 2:

a. Press

MAX/MIN/LIMITS

• once for positive

hour reset

• three times for

negative hour reset.

!

Four question marks

appear in lower display.

Step 3:

a. While the question

marks are displayed,

press PHASE/NEXT. A

password entry is now

required.

!

The password is 005.

b. Press PHASE/NEXT

each time a password

digit appears.

!

Checkmarks appear,

indicating a successful

reset.


5.8: Accessing the LM1/LM2 Set Limits

The EPM 5300P has two manual set limits which monitor the instantaneous readings and warn the user
of any abnormal conditions. Each limit detects readings either above or below a set level. The EPM
5200P does not have this feature.

SET LIMITS: Point when the relay changes position, if the EPM 5300P is equipped with the Relay Option
(Suffix -NL).

If a limit is exceeded, only the annunciator for LM1 and/or LM2 flash.

To view the setup of the LM1/LM2 set limits:

• Press MAX/MIN/LIMITS 2 times. to view the LM1 set limit momentarily.

• Press MAX/MIN/LIMITS 3 times to view the LM2 set limit momentarily.

• To locate readings that exceeded Limit 1, press MAX/MIN/LIMIT 3 times and then press

PHASE/NEXT. The display blanks, the middle display indicates L1, and annunciators for parameters
that exceeded Limit 1 illuminate.

• To locate readings that exceeded Limit 2, press MAX/MIN/LIMIT 4 times and then press

PHASE/NEXT. The display blanks, the middle display indicates L2, and annunciators for parameters
that exceeded Limit 2 illuminate.