Chapter 2— Operating the Printer

EasyCoder 3400e Bar Code Label Printer User’s Manual

25

3XXXU.029

SENSITIVITY NUMBER

57

120066102605140

120066102605140

Media sensitivity number: This illustration shows you where to find the media
sensitivity number. Note that some ribbon rolls have the media sensitivity number
printed inside of the core.

Use this three-digit number to optimize print quality and print speed on
your printer. You can achieve the best print quality on the printer by using
only Intermec ribbon and media products. The default sensitivity setting
for thermal transfer media is 567. For direct thermal media, the default
sensitivity setting is 470.

Use the PrintSet software, your third-party software, or the IPL command
set to change the MSN. If you want to see the current sensitivity setting of
your printer, print out a software configuration label.

To print a software configuration label

1

Turn the On/Off switch to the off position.

2

Press and hold the Feed/Pause button while turning the printer on. The
printer prints out a hardware configuration label.

3

Set the DIP switches to print out the software test label.

Top Bank

Set switches 1 through 6 and 8 off. Set switch 7 on.

Bottom Bank

Set switches 1 through 8 off.

4

Hold the Feed/Pause button down for 1 second. The printer prints out
the software configuration label.

5

Return the DIP switches to their original settings.

6

Turn the printer power off and then on.