1) typical assembly layout – Gas-Fired Products Infrared Radiant Tube Heater PTS Series User Manual

Page 13

Advertising
background image

Form

#43343330

–12–

May 08

60 FT. SYSTEM

50 FT. SYSTEM

20 FT. SYSTEM

30 FT. SYSTEM

40 FT. SYSTEM

LEGEND

Burner Box 10ft Aluminized Tube 24

Hole Flange

or

10ft Alumi-Therm Tube

6 Hole Flange

Coupling

10ft Aluminized or HRS

Tube model dependent

2ft Aluminized

Steel

Turbulator

sections

70 FT. SYSTEM

10 FT. SYSTEM

2ft Stainless

Steel

Turbulator

sections

Stainless Steel Turbulator

closest to burner PTS / U

40 only.

above.

7.1)

TYPICAL ASSEMBLY LAYOUT

Failure to do so may result in death, serious injury, property damage or illness

from Carbon Monoxide poisoning.

The heater must be assembled with the correct number of turbulator sections

and tube length for the rated heat input.

The turbulator must be installed in the last tube section as shown.

POISONOUS GAS AND SOOT HAZARD

















































MODEL

2 Ft. Turbulator

Sections

PTS/U 40

4

PTS/U 50

5

PTS/U 75

5

PTS/U 100

3

PTS/U 125

7

PTS/U 150

4

PTS/U 175

0

PTS/U 200

1

Advertising