0) attaching burner box assembly – Gas-Fired Products Infrared Radiant Tube Heater PTS Series User Manual

Page 25

Advertising
background image

Form

#43343330

–24–

May 08

12.0)

ATTACHING BURNER BOX ASSEMBLY

1. Attach the burner box and gasket to end of tube flange and secure with 1/4-20 locknuts.
2. Assemble the optional end reflector flush with the end of the main body reflector. Secure by sliding speed clips

onto the reflector edges. Evenly space the speed clips on the sides (one each side) and top (two required) of the
reflectors to provide a snug fit. Leave a 3" space between the end reflector and the burner box assembly.

3. The heater can be mounted horizontally or at an angle of up to 45 degrees maximum from horizontal.

When angle mounting, the burner box unit must be positioned upright as shown below. FAILURE TO INSTALL THE
BURNER BOX IN AN UPRIGHT POSITION WILL VOID THE MANUFACTURER’S WARRANTY.

Angle Mounting

Straight Tube Heaters

Burner

Box

Upright Position

Angle Mounting

U-Tube Heaters

Burner

Box

Upright Position

Reflector

1/4-20 Locknut

(QTY-3 per flange)

Mounting Flange

24 Hole for Aluminized Steel Tubes

6 Hole for Alumi-Therm Steel Tubes

Tube Flange

Gasket

Speed Clip

(QTY-4)

Optional

End

Reflector

Burner Box

Burner Box Suspension

Eye bolt

Turnbuckle

Failure to install the burner box

suspension chain will void

manufacturers warranty.

DO NOT lift burner or support it’s

weight using the TISS wire. It will

break under heavy load.


Advertising