5.0) SPECIFICATIONS

Orifice Size

Minimum *

Mounting Height

Model No.

Btu/hr

Input

Combustion Air

Plate

Part #

Natural Gas

Propane Gas

@

Horizontal

@

45º Angle

Turbulator

Qty.

PTS/PTU 40

40,000

#44140061

#32

(0.116)

#49

(0.073)

10 ft.

9 ft.

4

PTS/PTU 50

50,000

#44140064

3.5mm (0.138)

46

(0.081)

11 ft.

10 ft.

5

PTS/PTU 75

75,000

#44140063

#21

(0.159) 2.5mm (0.098)

13 ft.

12 ft.

5

PTS/PTU 100 100,000

#44140062

#12

(0.189))

#32

(0.116)

14 ft.

13 ft.

3

PTS/PTU 125 125,000

#44140066

#4

(0.209)

#30

(0.129)

14 ft.

13 ft.

7

PTS/PTU 150 150,000

#44140067

“A”

(0.234)

#27

(0.144)

15 ft.

14 ft.

4

PTS/PTU 175 175,000

#44140067

“E”

(0.250)

#23

(0.154)

16 ft.

15 ft.

0

PTS/PTU 200 200,000

#44140068

6.9mm (0.272) 4.1mm (0.161)

18 ft.

16 ft.

1


* MOUNT HEATERS AS HIGH AS POSSIBLE. Minimums are shown as a guideline for human comfort and uniform
energy distribution for complete building heating applications. Consult your Space-Ray representative for the
particulars of your installation requirements.

Type

Gas:

Gas-Pipe

Connection:

Tube

Diameter:

Flue

Connection:

1

Fresh Air

Connection:

1

Electrical

Supply:

Current

Rating:

Natural

or Propane

½” MPT

(Male)

4”

4” Round

4” Round

120 Volt,

60Hz, 1 Phase

1.74 Amp


1) See Section 16 for vent sizes when multiple heaters are connected into a common vent.

Module Electrical Rating:

Ignition System (direct spark):

Input Power-Control: 18-30 VAC 50/60 Hz (class 2
transformer)
Input Power-Line: 120 VAC (L1, IND contacts only)
Gas Valve Rating: 2.0 A @ 24 VAC (max.)
Combustion Blower Rating: 3.0 FLA @ 120 VAC
1/4 H.P. Motor
Flame Sensitivity: 0.7 microamps minimum

15 second trial for ignition period
15 second pre-purge period
60 second inter-purge period
30 second post-purge period
3 tries for ignition (separate flame sensor).


6.0) PACKING

LIST

A) PTS/PTU Burner Package

QTY

Burner Box Assembly (Refer to the following chart for Package Part Numbers)

1

4”ID x 4”Lg Flue Adapter Collar (#30504500) ...................................................................1
Fastener Kit – Burner Box Attachment/Flue Adapter Collar (#42907040)....................1
containing: #10 x 1/2” Self-Drilling Screws (#02189020)..............................2

¼ - 20 Locknuts (#02167010) ..............................................................3

Tube Flange Gasket (#42921000).......................................................................................1

Turbulator 24” Long (#44152240) *See chart above for required quantities.

*

Installation & Operation Instructions (#43343330)..........................................................1

Turnbuckle (#30545040) ......................................................................................................1

Gas connector 5/8” OD x 36” (#30302360) .......................................................................1

Advertising
This manual is related to the following products: