Gas-Fired Products Infrared Radiant Tube Heater PTS Series User Manual

Page 45

Advertising
background image

Form

#43343330

–44–

May 08





Remove blockage. Rest

art

troubleshooting.

Cont

act factory for

assist

ance.

No

Ye

s

No

No

Ye

s

Does the amber light st

ay on p

ast 10

seconds?

No

Ye

s

Check the micro Amp

s at the FC-FC+

terminals of the module is it greater than

0.7µA

w

ith

flame.

Turn on the gas valve?

Does LED on the ignition module flash three times?

Replace ignition module.

Check flame sense wire does it have continuity?

No

Ye

s

Check

vent

and

fresh

air lengths, are they within the maximum permissible?

Cont

act factory for

assist

ance.

Replace flame sense wire.

No

Ye

s

Check air plate st

amped p

art

numbers.

Are they

correct?

No

Ye

s

Check turbulator

, are

the

correct

number

of

lengths inst

alled?

Rep

air or replace

jumper check all wire terminals.

Change number of turbulators.

Adjust terminal connection. Rest

art

troubleshooting.

No

Ye

s

No

Ye

s

Remove burner casting and check the orifice. Is it clean and free from blockage?

No

Ye

s

Check the pressure across the air switch during hot running is it higher than the minimum required?

Check gas pipe sizing,

regulators

and

system supply gas pressures.

Adjust manifold pressure. Rest

art

troubleshooting.

Troubleshoot Ends

No

Ye

s

Is

the

knob

on

the

gas

valve turned to the ON position?

No

Ye

s

Through the inspection window is there a flame visible during st

art up?

No

Ye

s

Is

the

heater

properly

grounded?

Correct grounding problem.

No

Ye

s

Check

the

terminal

on

the flame sense electrode, is it tight?

No

Ye

s

Remove and inspect flame sense electrode. Is it clean and the ceramic int

act?

Rep

air or replace

flame sense electrode.

Ye

s

Check

the

gas

supply

pressure with all the heaters on. Does it st

ay above the

minimum required?

No

No

Ye

s

Check the air int

ake

and vent are there any blockages?

No

Ye

s

Is

the

heater

properly

grounded?

No

Ye

s

No

Ye

s

No

Ye

s

No

Ye

s

No

Ye

s

Remove

blower

is

the

wheel free from dirt and dust?

Replace air switch

No

Ye

s

Remove blower does the

wheel

turn

freely?

Replace blower assembly

.

Replace air plate.

Cont

act factory for

assist

ance.

No

Ye

s

Does the amber light st

ay on until the

thermost

at turns of

f?

See next p

age for

troubleshooting sequence.

No

Ye

s

Replace ignition module.

No

Ye

s

Does LED on the ignition module flash once?

Ye

s

Does LED on the ignition module flash three times?

Af

ter an initial step

opening is the manifold gas pressure correct?

Correct grounding problem.

Remove blockage. Rest

art

troubleshooting.

Clean blower wheel. Rest

art

troubleshooting.

Cont

act factory for

assist

ance.

Check the micro Amp

s at the FC-FC+

terminals of the module is it greater than

0.7µA

with

flame.

Check

the

terminal

on

the flame sense electrode, is it tight?

Check flame sense wire does it have continuity?

Replace flame sense wire.

Adjust terminal connection. Rest

art

troubleshooting.

Remove and inspect flame sense electrode. Is it clean and the ceramic int

act?

Rep

air or replace

flame sense electrode.

Cont

act factory for

assist

ance.