Adjustment and Troubleshooting

Service Manual

4-67

5) Paper Empty without indication

Description: The paper empty message does not appear in the LCD when the paper cassette is empty.

1. Deformed paper sensor

actuator or faulty sensor.

Replace the defective actuator.

Replace the SMPS PBA or MAIN
PBA as appropriate.

2. SMPS PBA or Main PBA

is defective.