READING ACTUAL VALUES
1. IGNITION : Position 1
2. Set temperature selection to 72 degrees F (Press v and ^ simultaneously).
3. Press the AUTO button.
4. Press the REST button for more than 5 seconds.
5. The display will alternately show the number "01" and the in-car temperature or "LO" if there is an open

circuit or "HI" if there is a short circuit.

6. Press the "Top Air Outlet" button to increase the component tested and the "Bottom Air Outlet" button to

decrease the component number tested.

7. Press the REST button to end the test program.

COMPONENT UNDER TEST

Number

Component

01

In-Car Temperature Sensor with Aspirator Blower (B10/4)

02

Outside Temperature Sensor (B10/5)

03

Heater Core Temperature Sensor (B10/1)

05

Evaporator Temperature Sensor (B10/6)

06

Engine Coolant Temperature (ECT) Sensor (A/C) (B10/8)

07

Refrigerant Pressure in Bar

08

Blower Control Voltage

09

Software Status of A/C Pushbutton Control Module

15

Selected In-Car Temperature

20

Version Code

21

Engine Speed in RPM

22

A/C Compressor Speed in RPM

23

Vehicle Speed in km/h

50

Not Used

51

Number of Current Poly-V Belt Slip Recognitions

52

Number of Stored Poly-V Belt Slip Recognitions

FAULT DIAGNOSIS
1 IGNITION : Position 1
2 Press the V button until "LO" appears on the display.
3 Within 20 seconds press the REST and BLOWER buttons simultaneously for more then 2 seconds.
4 The LED in the RECIRCULATE button flashes and "dI R" appears on the display
5 Press the AUTO button until all DTC's are displayed and recorded. Continuous faults are displayed first. if

no faults are stored, "En d" is displayed. Press AUTO again to retrieve intermittent faults. If no intermittent
faults are stored, "En d" is displayed.