Mocomtech CIM-550 User Manual

Page 103

Advertising
background image

CiM-550 IP Enabled Satellite Modem

Rev. 2

Remote Control

CD/CIM550.IOM

77

Parameter
Type

Command
(Instruction

Code and
qualifier)

Arguments for

Command or

Response to
Query

Description of arguments
(note that all arguments are ASCII numeric

codes, that is, ASCII codes between 48 and 57)

Response to Command

(target to controller)

Query
(Instruction

Code and
qualifier)

Response to

query
(target to
controller)

affect this value. Example reply: NUS=198

Rx Eb/No

N/A

4 bytes,

numerical

Query only.
Unit returns the value of Ebi/No, between 0 and
16dB. Resolution 0.1 dB. Returns 99.9 if demod is

unlocked. Example: EBN=12.3 (which is Eb/No =

12.3 dB) For values greater than 16.0 dB, the reply

will be EBN=+016.

N/A

EBN?

EBN=xx.x (see

description for
details of

arguments)

RX Coarse

AGC

N/A

2 bytes,
numerical

Query only.
Unit returns the vaue of Coarse AGC setting,
between 0 and 99
Example: AGC=76

N/A

AGC?

AGC=xx (see

description for
details of

arguments

Rx Freq
Offset

N/A

5 bytes,
1st , + or -,
next 4 bytes
numerical

Query only.
Unit returns the value of freq. offset of the carrier

being demodulated. Values range from ±0 to ± 30

kHz, 100 Hz resolution.Example: RFO=+02.3
(offset is +2.3 kHz) Returns 99999 if the demod is

unlocked.

N/A RFO?

RFO=nxx.x

(see

description for

details of

arguments)

Buffer Fill

State

N/A

2 bytes,
numerical

Query only.
Unit returns the value of the buffer fill state. Values

range from 1 to 99% .Example: BFS=33 (buffer fill

state is 33%) Returns 00 if demod unlocked.

N/A

BFS?

BFS=xx (see

description for

details of

arguments)

Rx BER

N/A

5 bytes

Query only.
Unit returns the value of the estimated corrected
BER in the form a.b x 10exp-c. Fist and second

bytes are value, 3rd and 4th bytes are the

exponent. Returns 99999 if demod is unlocked.
Example: BER=4.8E3 (BER is 4.8 x 10-3)

N/A BER?

BER=a.bEc
(see
description for

details of

arguments)

Redundancy
State

N/A

1 byte, value of

0 or 1

Query only.
Returns the redundancy state of the unit, where:

N/A

RED?

RED=x (see

description for
details of

Advertising