Table 13-45. odu unit oids, 11 odu u – Mocomtech CIM-550 User Manual

Page 283

Advertising
background image

CiM-550 IP Enabled Satellite Modem

Rev. 2

SNMP interface

CD/CIM550.IOM

257

13.5.1.11 ODU U

NIT

P

ARAMETERS

Table 13-45. ODU Unit OIDs

OID Description

oduUnitMuteMode

Unit mute. Can be set to:

0 Unmute

1 Mute

oduUnitColdStart

Unit cold start. Can be set to:

0 Disabled

1 Enabled

oduUnitAutoFaultRecovery

Auto fault recovery. Can be set to:

0 Disabled

1 Enabled

oduUnitExtRefFaultLogic

External reference fault logic. Can be set to:

0 Disabled

1 Enabled

oduUnitRefOscAdjust

Reference oscillator adjust. Can be between 0 and 255.

oduUnitLNACurrentSource

LNA current source. Can be set to:

0 Disabled

1 Enabled

oduUnitLNACurrentWindow

LNA current windows. Can be set to:

20 20

Percent

25 25

Percent

30 30

Percent

35 35

Percent

40 40

Percent

45 45

Percent

50 50

Percent

99 Disabled

OduUnitLNAFaultLogic

LNA fault logic. Can be set to:

0 Disabled

1 Enabled

oduUnitRedundancyMode

Redudancy mode. Can be set to:

0 Manual

1 Auto

oduUnitRedForceSwitch

Force redundant switch. Can be set to 1 (yes) to issue
command.