Step Procedure

1

From the Main Menu, select Administration sub-menu.

2

From the Administration menu, select Operations and Maintenance sub-menu.

3

From the Operations and Maintenance menu, select Database Operations sub-menu

4

From the Database Operations menu, select Restore Factory Default option

5

Confirm when prompted.

This will erase any user configuration and restore the CiM to factory default
configuration.

14.2.7 C

I

M 1 C

ONFIGURATION

CiM has 2 data interfaces - a LAN interface and a WAN interface. The LAN interface is
a 10/100baseT Ethernet port (fei0). The WAN interface is the serial synchronous HDLC
interface (hdl0). The Ethernet MAC address is factory assigned and cannot be changed.

14.2.1.1

S

ETTING

IP A

DDRESS

(

ES

)

Step Procedure

1

From the Main Menu select Interface Configuration sub-menu.

2

From the Interface Configuration Menu select Ethernet Interface (fei0)

3

Set IP Address to 172.16.10.10

4

Set Subnet Prefix Length to 24

5

From the Interface Configuration Menu select Satellite/HDLC Interface (hdl0).

6

Set IP Address to 10.1.1.1

7

Set Subnet Prefix Length to 24

8

Set RX – Enable/Disable and TX – Enable/Disable to Enable.

9

From Receive HDLC Channel Address menu set HDLC Addr 1 to 1 (0x0001)

The other parameters can be left to their factory default settings.