Two-wire multidrop network, Up to 4000 ft – Matrox Electronic Systems 4SIGHT-M User Manual

Page 64

Advertising
background image

64 Chapter 5: Matrox 4Sight-M hardware reference

On Matrox 4Sight-M, you can activate internal resistor termination to eliminate
distortion caused by these reflections. To connect internal resistor termination on
your unit, adjust the internal dip switch accordingly.

❖ Note that on a Matrox 4Sight-M unit in a multidrop network, internal resistor

termination is available exclusively for the receivers.

Two-wire multidrop
network

The following illustrates a typical RS-485 two-wire multidrop network that
Matrox 4Sight-M cannot support.

Note that because the driver and receiver for the Matrox 4Sight-M serial port are
always enabled, the unit cannot be connected to a typical RS-485 two-wire
multidrop network shown below.

D

R

A

B

A

B

TX

RX

ENABLE

D

R

A

B

A

B

TX

RX

ENABLE

D

R

A

B

A

B

TX

RX

ENABLE

D

R

A

B

A

B

TX

RX

ENABLE

Rt

Rt

TERMINATION RESISTORS AT BOTH ENDS ONLY

UP TO 4000 FT

D Driver

-

Circuit ground or
circuit common

R - Receiver

-

Use the dip switch to
enable or disable the
resistor

MATROX IMAGING est distribué par TECHWAY - www.techway.fr - [email protected] - +33 (0)1 64 86 58 30