2 cpu diagnostic leds – Intel SE8500HW4 User Manual

Page 125

Advertising
background image

Intel® Server Board Set SE8500HW4

Error Handling

Revision 1.0

Intel order number D22893-001

113

Code

Description

0xE2

Initial memory found, configured, and installed correctly

0xE,

0xE3

Reserved for initialization module use (PEIM)

DXE Core:

0xE4

Entered EFI driver execution phase (DXE)

0xE5

Started dispatching drivers

0xE6

Started connecting drivers

DXE Drivers:

0xE7

Waiting for user input

0xE8 Checking

password

0xE9

Entering the BIOS setup

0xEA Flash

update

0xEE

Calling Int 19. One beep unless silent boot is enabled.

0xEF Unrecoverable

Boot

failure/S3 resume failure

Runtime Phase/EFI OS Boot:

0xF4

Entering Sleep state

0xF5

Exiting Sleep state

0xF8

OS has requested EFI to close boot services

0xF9

OS has switched to virtual address mode

0xFA

OS has requested the system to reset

PEIM/Recovery:

0x30

Crisis recovery has been initiated because of a user request

0x31

Crisis recovery has been initiated by software (corrupt flash)

0x34

Loading crisis recovery capsule

0x35

Handing off control to the crisis recovery capsule

0x3F

Unable to complete crisis recovery.

12.1.2

CPU Diagnostic LEDs

The BMC provides one amber LED per processor. The LEDs are turned on when a CPU has an
error.

Table 90. Processor Diagnostic LED Locations

LED Reference Designator

Processor

DS5C1 1

DS5C2 2

DS5C3 3

DS5C4 4

Advertising