2 power-down sequence – Intel SE8500HW4 User Manual

Page 71

Advertising
background image

Intel® Server Board Set SE8500HW4

Electrical Specifications

Revision 1.0

Intel order number D22893-001

59

Table 34. Typical Power-Up Timings

Ref

Description

Max Typical

Min

t1

Time from front-panel power button push to BMC asserting the power button to the
chipset. This includes the private store update for Pwr State change, which is on the
order of 500ms + overhead, which accounts for other task completion time like Init
Agent. BMC also debounces signal for 50ms.

2s 1s

50ms

t2

Time from BMC asserting power button to chipset, until chipset responds with
SLP_S5.

– 16ms

60µs

t3

Time from when SLP_S5 is asserted, to when BMC asserts PS_ON_L to complete
system power-on.

1s 97ms 50ms

t4

Time from when BMC has completed driving its power-on signals, to when system
asserts power good back to BMC.

– 500ms

250ms

8.2.2 Power-Down

Sequence

POWER_SW_L

(I)

SM_PWRBTN_L

(O)

SLP_S5P_L

(I)

PS_ON_L

(O)

SYS_PWROK

(I)

t1

t2

t4

t3

Figure 15. Typical Power-Down Sequence

Advertising