Processor Thermal/Mechanical Information

Thermal and Mechanical Design Guidelines

25

Figure 9. Case Study #4: A “Top Mount Fan” PSU is located next to Processor in μATX

Chassis for System Thermal Performance Improvement

2.4.3

Summary

In summary, heatsink design considerations for the Intel Celeron processor 200

sequence on the Intel Desktop Board D201GLY2 include:

• The heatsink temperature

TS-TOP-MAX

which is a function of system thermal

performance must be compliant in order to ensure processor reliability.

• Heatsink interface to die surface characteristics, including flatness and roughness.

• The performance of the thermal interface material used between the heatsink and

the die.

• The required heatsink clip static load, 9.9 lbf ± 1.2 lbf, throughout the life of the

product (refer to Section 2.1.2.2 for further information).

• Surface area of the heatsink.

• Heatsink material and technology.

• Volume of airflow over the heatsink surface area.

• Development of airflow entering and within the heatsink area.

• Physical volumetric constraints placed by the system.

§