Intel CELERON 200 User Manual

Page 32

Advertising
background image

Thermal Metrology

32

Thermal and Mechanical Design Guidelines

Figure 12. Locations for Measuring Local Ambient Temperature, Passive Heatsink

3MM AWAY FROM HEATSINK SIDES

TOP VIEW

POTISTION THERMOCOUPLES (X4)
AT LOCATIONS AS INDICATED
TO MEASURE T

A

.

TC1

TC2

TC3

TC4

HALF OF HEATSINK FIN HEIGHT

SIDE VIEW

3MM AWAY FROM HEATSINK SIDES

TOP VIEW

POTISTION THERMOCOUPLES (X4)
AT LOCATIONS AS INDICATED
TO MEASURE T

A

.

TC1

TC2

TC3

TC4

HALF OF HEATSINK FIN HEIGHT

SIDE VIEW

NOTE: Drawing Not to Scale

It is recommended that full and routine calibration of temperature measurement

equipment be performed before attempting to perform temperature measurement.

Intel recommends checking the meter probe set against known standards. This

should be done at 0 ºC (using ice bath or other stable temperature source) and at an

elevated temperature, around 80 ºC (using an appropriate temperature source).

Wire gauge and length also should be considered as some less expensive

measurement systems are heavily impacted by impedance. There are numerous

resources available throughout the industry to assist with implementation of proper

controls for thermal measurements.

3.3

Processor Power Measurement Metrology
Recommendation

This section recommends a metrology to measure power consumption of the Intel

Celeron processor 200 sequence on the Intel Desktop Board D201GLY2. Should there

be any modification of motherboard layout or design, contact Intel field sales

representative or product marketing staff for clarification of this metrology.

Advertising