Thermal Metrology

Thermal and Mechanical Design Guidelines

29

Figure 10 illustrates the combination of the different thermal characterization

parameters.

Figure 10. Processor Thermal Characterization Parameter Relationships

3.1.1

Example

The cooling performance, Ψ

JA,

is then defined using the principle of thermal

characterization parameter described above:

• The junction temperature

TJ-MAX

and thermal design power TDP given in the

processor datasheet.

• Define the allowable heatsink temperature for processor, T

S-TOP-MAX

.

The following provides an illustration of how one might determine the appropriate not

related to any specific Intel processor thermal specifications, and are for illustrative

purposes only.

Assume the TDP, as listed in the datasheet, is 20 W and the maximum junction

temperature 20 W is 90 °C. Assume as well that the system airflow has been

designed such that the local ambient temperature is 42 °C, and Ψ

HS_BASE

= 0.3 °C/W.

Then the following could be calculated using Equation 2:

Ψ

JA

= (T

J

– T

A

) / TDP = (90 – 55) / 20 = 1.75 °C/W