System Thermal/Mechanical Design Information

38

Thermal and Mechanical Design Guidelines

4.2

Environmental Reliability Testing

4.2.1

Structural Reliability Testing

Structural reliability tests consist of unpackaged, board-level vibration and shock tests

of a given thermal solution in the assembled state. The thermal solution should meet

the specified thermal performance targets after these tests are conducted; however,

the test conditions outlined here may differ from your own system requirements.

4.2.1.1

Random Vibration Test Procedure

Duration: 10 min/axis, 3 axes

Frequency Range: 5 Hz to 500 Hz

Power Spectral Density (PSD) Profile: 3.13 G RMS

Figure 17. Random Vibration PSD

0.001

0.01

0.1

1

10

100

1000

Frequency (Hz)

PSD

(

g

^

2

/H

z

)

3.13GRMS (10 minutes per axis)

5 Hz

500 Hz

(5, 0.01)

(20, 0.02)

(500, 0.02)

4.2.1.2

Shock Test Procedure

Recommended performance requirement for a motherboard:

• Quantity: 3 drops for + and - directions in each of 3 perpendicular axes (i.e.,

total 18 drops).

• Profile: 50 G trapezoidal waveform, 170 in/sec minimum velocity change.

• Setup: Mount sample board on test fixture.

Advertising