Samples - 1 to 30

Subgroups - 1 to 50

Units - lbin, lbft, Ncm, Nm, kgcm, kgm, ozin

Direction - Right or Left

Cycle End Time - 0.1s, 0.2s, 0.5s, 1.0s, 2.0s, 5.0s, 10.0s

Joint Type - Hard, Medium, Soft

Torque Threshold - 5% to 90% of tool’s maximum torque rating

Torque LSL - Torque Threshold +.01 to 100% of max -.01

Torque USL - Torque USL +.01 to 100% of max

Angle LSL - 0° to Angle USL - 1

Angle USL - 1° to 3000°

Trace Saved? - Yes or No

Cont. Output - Yes or No

Auto Print - Yes or No

Use the

keys to scroll through the menu options

(displayed 1 per screen), and press

ENTER to edit.

Menu options are edited by using the

keys to scroll through

the options and then pressing

ENTER.

To exit without changing, press

ESCAPE.

To exit from any screen, press

ESCAPE.

Cycle End Time

When the applied torque is removed, the wrench does not

immediately store the data. Instead it waits for the Cycle End Time

to count down to zero. This allows time for the operator to adjust

grip or ratchet the wrench. The Cycle End Time can be altered in

Yield Control Mode Setup.

Auto Print

The Auto Print feature allows the wrench to directly output

measurements to a printer or PC as they are taken. The

information appears as a single line of text showing the: date,

time, peak torque, torque compared to specifications, peak angle,

angle compared to specifications, and direction of fastening. The

formatting and spacing will be different based upon the number of

columns the operator has chosen under Printer Setup.

Continuous Output

Setting the Cont. Output to “Yes” in peak measurement modes

causes the wrench to output fastener torque on a second- by-

second basis. This output can be sent to either a printer or a PC

using the supplied RS232 cable.

Trace saved?

Set “Trace saved?” to yes after a reading to store it in the Expert

Wrench memory. A trace includes information about the

configuration used to take the reading as well as a table of torque

and angle values. The traces can be uploaded to a PC using the PC

Comms software (sold separately). Up to 10 traces can be saved

in memory.

Canceling a Reading

To discard a reading, use the

keys to highlight the

Cancel Icon and press

ENTER. Press

ENTER again to

confirm when prompted ‘Cancel reading?’

View Statistics

To view statistics about previous readings, use the

keys to

highlight the

Stats Icon and press

ENTER. This brings you

to a table of calculated values for Mean X, R, σ, Cp, Cpk, Cm, Cmk,

CAM derived from the recorded torque and angle data. Different
pages of the table can be viewed by pressing the

keys.

Custom Control

In this mode the user can set a series of up to 20 configurations

whose settings will be saved for future access through the

Custom Control List. These can be torque, angle, or yield control

configurations. To access Custom Control, scroll to Custom

Control in the main menu and press ENTER. This brings up the

Custom Control List. Using the UP and DOWN arrow keys, select a

configuration, 1 through 20, and press ENTER. If this configuration

has been programmed previously, just wait for the box that says

“WAIT” to disappear and for the two red LEDs to be replaced by a

single yellow. If this configuration is not set, or you wish to change
the settings, use the

keys to highlight the

Setup Icon

and press

ENTER to access the Custom Setup Menu. In this

menu, you can choose:

Samples - 1 to 30

Subgroups - 1 to 50

Mode - Torque, Angle, Yield

Units - lbin, lbft, Ncm, Nm, kgcm, kgm, ozin

Direction - Right or Left

Cycle End Time - 0.1s, 0.2s, 0.5s, 1.0s, 2.0s, 5.0s, 10.0s

Joint Type - Soft, Medium, Hard **(only if Mode is set to Yield)

Torque Threshold - 5% to 90% of tool’s maximum torque rating

Torque LSL - 5% of max +.01 to 100% of max -.01

Torque USL - 40% of max +.01 to 100% of max

Angle LSL - 0° to Angle USL - 1

Angle USL - 1° to 3000°

Trace Saved? - Yes or No

Cont. Output - Yes or No

Auto Print - Yes or No

When the desired settings have been chosen, exit the Custom

Setup Menu by pressing ESC. The wrench will now function in the

same way as the selected Mode (i.e., if Torque was chosen, tool will

work the same as in Torque Control Mode). Refer to that section of

the manual for specific tightening instructions.

The default display is similar to that of the current tightening

mode. The bottom left corner displays the number of the Custom
configuration that is currently in use. Pressing the

keys scrolls

through the other display screens the same manner as in the other

modes.

MAIN SETUP MENU

Use the Main Setup Menu to change the following:

Date and Time (plus date format)

Regional Settings (language and decimal point style)

Power Settings (battery charge status, battery auto off time,

Backlight auto off time, and battery type [Ni-Mh or alkaline]) See

below

Printer Setup (40 or 80 columns)

Buzzer (enable or disable)

Password