Ingersoll-Rand ETW-E75 User Manual

Page 7

Advertising
background image

04581922_ed4

EN-6

EN

SECTION 3 - OPERATING INSTRUCTIONS

REMOVING AND REPLACING THE BATTERIES

It is recommended that the wrench is turned off before batteries

are removed so that any current data can be backed up (see Auto

Power Off function). If this is not done, when the wrench is turned

on it will show memory checksum errors (or a message advising

power was removed incorrectly).

Removing

To remove the batteries from the Expert Torque Wrench:

Unscrew the end cap (counter-clockwise) as shown and remove.

Tilt the Expert Torque Wrench slightly to allow the batteries to

slide out.

Replacing

Place Ingersoll Rand battery pack ETW-EBP into the Expert Torque

Wrench as shown, making sure the Positive (+) end of the battery is

facing into the device and the Negative (-) end is towards the cap.

Replace the cap by carefully screwing it clockwise against the

spring pressure, taking care to keep it at a right angle to the Expert

Torque Wrench body to avoid cross-threading.

Note: If the Expert Torque Wrench does not switch on and the LED is

showing a constant amber light, the Expert Torque Wrench will have
to be reset. Press the

ESCAPE and

keys simultaneously and

hold for a few seconds to perform a hardware reset.

INSERT NEW BATTERIES AS SHOWN.

CHECK POLARITY OF BATTERIES -

MINUS (-) TO END CAP

UNSCREW END CAP TO

ACCESS BATTERY

COMPARTMENT

RECHARGING THE ETW-EBP BATTERIES

The Power Menu will show the available charge left on the battery

- see Setup Menu / Power Menu.

When the menu show 3 bars left (30%), the wrench will display a

flashing battery symbol at the bottom of the display, on any screen.

This indicates that the battery charge is low and the battery should

be recharged.

As a precautionary measure, the wrench will turn off the

backlight to conserve the remaining battery charge.

As the battery charge falls further, the wrench will show a Battery

Urgent message and will then turn off the wrench. If an attempt is

made to turn the wrench on while it is in this state, then it will not

power up. The batteries should be immediately recharged.

You may charge the Ingersoll Rand rechargeable battery pack in

the wrench with a special cable connecting the Ingersoll Rand

supplied charger to the RS232 port of the wrench.

WARNING

Only use the wrench and charger to recharge the

Ingersoll Rand supplied battery pack.

RED DOT

ATTACH CHARGER

LEAD HERE

Note: The Expert Torque Wrench cable has a 5 pin round connector

to the wrench. This means the previous 4 pin cables for earlier Expert

Torque Wrench models cannot be used.

Note: While the rechargeable battery pack is being charged in the

wrench, the wrench cannot be operated.

Hint: Line up the red dots on connector and plug.

POWERING ON

To switch on the Expert Torque Wrench, press any arrow
key.

If the wrench is switched on after it has powered down, it will

return to the menu/screen from which it was powered down.

HARDWARE RESET

To perform a hardware reset, press the red

ESCAPE and UP

keys together.

Note: Performing a Hardware Reset resets the Expert Torque Wrench.

You will be warned to save data and perform a software reset.

AUTO POWER OFF FUNCTION

As an energy saving feature, the Expert Torque Wrench is

programmed to power down automatically if it has received no

user input for a predefined period (10 mins is the default setting,

but can be set from 1 minute to never off). Pressing any key will

restore the unit to the last display prior to powering off. This is to

avoid the possibility of loss of data due to an interruption to the

operator’s activities while using the Expert Torque Wrench.

To switch off without waiting for the Auto Power Off, select the

Power Off option from the Main Menu. An alternate method is to

go into Main Setup Menu / Power Settings and select the Power
off icon

.

Advertising
This manual is related to the following products: