IMPORTANT: Read all instructions before calibrating

the AutoTrac Controller

AutoTrac calibration should completed without
an implement connected to the tractor to avoid
damage to the tractor or implement.

Drive tractor slowly at full throttle for approximately
2 to 5 minutes to bring hydraulic fluid to operating
temperature before beginning calibration procedure.

Calibration procedure will require a large, open, level
surface to complete the required steps.

Calibration procedure must be completed prior to using
AutoTrac for the first time.

Calibration procedure must be complete with a passing
status prior to using AutoTrac. If a passing status is not
achieved then AutoTrac will not work.

NOTE: At any time during calibration, the operator

may take control of the system by grabbing the
steering wheel or stopping the machine.

To begin calibration select Recalibrate Hydraulic System
button (C) form the Calibration Assistant Main screen.

PC13385

—UN—20APR1

1

Calibration Assistant Main Screen

A—Home
B—Reset controller to Factory

Defaults

C—Recalibrate Hydraulic

System

D—Exit Calibration Assistant

To proceed with the calibration process select yes (B) to
proceed or select no (C) to cancel.

A—Home
B—Yes

C—No

PC13387

—UN—20APR1

1

Recalibrate Hydraulic System