John Deere AUTOTRAC OMPFP11320 User Manual

Page 59

Advertising
background image

GS3 2630 Advanced Settings

CF86321,000027D -19-16MAY11-2/9

Continued on next page

CF86321,000027D -19-16MAY11-3/9

Line Sensitivity Heading

Determines how aggressively AutoTrac responds to
heading errors.

Higher settings: Result in more aggressive response to
vehicle heading error.

Lower settings: Result in less aggressive response to
vehicle heading error.

PC13571

—UN—04MA

Y1

1

Line Sensitivity Heading

Heading Lead

Determines the impact of yaw rate (vehicle rate of turn)
on tracking performance. This can be thought of as a
look-ahead parameter. Large adjustments may result in
poor performance.

Higher settings: Results in more aggressive response
to vehicle twist.

Lower Settings: Results in less aggressive response to
vehicle twist.

PC13573

—UN—04MA

Y1

1

Heading Lead

45-5

090811

PN=59

Advertising