GS3 2630 Advanced Settings

CF86321,000027D -19-16MAY11-8/9

CF86321,000027D -19-16MAY11-9/9

Curve Sensitivity

Determines how aggressively AutoTrac responds to a
curve in the track. This setting affects performance in
curve track guidance only.

Higher settings: Turns the vehicle in a smaller radius
(tighter) around the curve.

Lower Settings: Turns the vehicle in a larger radius
around the curve.

PC13575

—UN—04MA

Y1

1

Curve Sensitivity

Curve Sensitivity

PC8944

—UN—21FEB06

Curve Sensitivity Too Low

PC8943

—UN—21FEB06

Curve Sensitivity Too High

•

Tune Curve Sensitivity while operating in Curve Track

•

If vehicle turns outside of the curve adjust sensitivity
higher

•

If vehicle turns inside of the curve adjust sensitivity lower.

Find the combination of values that works best for the
vehicle.

PC8999 —UN—08MAR06

A—Desired Track—Broken

Line

B—Actual Track—Solid Line