Table 18: Power Cord Specifications

Specifications

Country

UL-approved and CSA-certified

Flexible cord minimum spec: No. 18 (1.5 mm2SVT or
SJT, 3-conductor

Current capacity of 10A minimum

Earth-grounding attachment plug with NEMA 5-15P
(10A, 125V) configuration

United States and Canada

Table 19 on page 60

list environmental specifications.

Table 19: Environmental Specifications

Value

Specification

41° to 104° F (5° to 40° C)

Operating temperature

-40° to 158° F (-40° to 70° C)

Storage temperature

8% to 90% noncondensing

Relative humidity (operating)

5% to 95% noncondensing

Relative humidity (storage)

10,000 ft (3,048 m)

Altitude (operating)

40,000 ft (12,192 m)

Altitude (storage)

Heat dissipation rates depend on the traffic rate and the number and type of features
you have enabled.

Table 20 on page 60

provides guidelines.

Table 20: Heat Dissipation Guidelines

BTU/hour

Watts

Specification

273

80

Minimum

375

110

Maximum

Copyright © 2012, Juniper Networks, Inc.