Sharp Digital Laser Copier/Printer AR-5127 User Manual

Page 33

Advertising
background image

AR-5127 SIMULATION 8 - 5

The magnification ratio can be selected in the range of 50% – 200% in
9 steps with

keys.

(AB series) 50

70

81

86

100

115

122

141

200

(Inch series) 50

64

77

95

100

121

129

141

200

The scan counter is displayed during execution.

Note: Executable only when the SPF/RSPF is installed.

Operation/procedure
The operations of sensors and detectors in the SPF section are dis-
played.
The active sensors and detectors are highlighted.

Note: Executable only when the SPF/RSPF is installed.

Operation/procedure
The names of the loads which can be operated are displayed. Select
the load to be checked with the 10-key.

The motor for 10sec, the solenoid ON for 500msec, OFF for 500msec.
(20 times)
Note: Executable only when the SPF/RSPF is installed.

Operation/procedure
Used to display the operations of sensors and detectors in the finisher
section.
The active sensors and detectors are highlighted.

Note: Executable only when the finisher is installed.

Operation/procedure
The names of the loads which can be operated are displayed. Select
the load to be checked with the key.

During execution, [EXEC] is highlighted. Under this state, press the
[BACK] key to interrupt the operation.

(Initial screen)

(Input/Selection screen) (Executing screen)

Magnification ratio

50% to 200%

Default

100%

Document size

Varies depending on the destination.

Single/duplex

Selectable only when RSPF is installed, fixed
(single) for SPF.

Set number of times

1 to 999 (0: Continuous operation)

2-2

Purpose

Operation test/check

Function
(Purpose)

Used to check the operation of sensors and detectors
in the SPF unit and the related circuit.

Section

SPF

Item

Operation

EMPS

Empty sensor

DLS1

Tray length sensor (small)

DLS2

Tray length sensor (large)

DWS1

Tray width sensor (small)

DWS2

Tray width sensor (middle)

DWS3

Tray width sensor (large)

FGOD

Paper feed cover sensor

DFD

Document entry detection sensor

RDD

Document exit sensor

OPCLS

Book sensor

2-3

Purpose

Operation test/check

Function
(Purpose)

Used to check the operation of the loads in the SPF
unit and the control circuits.

Section

SPF

Item

Operation

(Initial screen)

(Executing screen)

1:DTM-F

SPF motor forward rotation

2:DTM-R

SPF motor reverse rotation

3:DFSOL

SPF document pick-up solenoid

4:CLH

SPF document exit transport clutch

5:GSOL

RSPF document exit gate solenoid

6:RSOL

RSPF document pressure solenoid

Sim2-1 SPF AGING

115% A3

1SIDE

100%

2SIDE

86%

ZOOM <100%>

0

Sim2-1 SPF AGING

115% A3

1SIDE

100%

2SIDE

86%

ZOOM <100%> EXEC

Sim2-1 SPF AGING

115% A3

1SIDE

100%

2SIDE

86%

ZOOM <100%>

EXEC

Sim2-2 SENSOR CHECK

EMPS

DLS1 DLS2

DWS1 DWS2 DWS3

FGOD

DFD RDD

OPCLS

Sim2-3 OUTPUT CHECK

1:DTM-F 4:CLH

2:DTM-R 5:GSOL

3:DFSOL 6:RSOL

EXEC

2

Sim2-3 OUTPUT CHECK

1:DTM-F 4:CLH

2:

DTM-R

5:GSOL

3:DFSOL 6:RSOL

EXEC

2

3

3-2

Purpose

Operation test/check

Function
(Purpose)

Used to check the operation of sensor and detector in
the finisher and the related circuit.

Section

Sorter/Finisher

Item

Operation

INPD

Finisher paper entry sensor

FWPS

Paper width sensor

JGHP1

Side guide plate HP sensor

JGHP2

Rear edge plate HP sensor

JGPD

Tray paper empty sensor

T1OD

1st tray exit sensor

T1PF

1st tray paper full sensor

PGOP

JAM processing PG open/close detection sensor

T2OD

2nd tray transport sensor

OFHP

Offset HP sensor

T2UP

Tray position sensor (upper)

T2DN

Tray position sensor (lower)

JGDSW

Tray jam processing interlock

EVRE

Lift-up drive control sensor

STHP

Staple HP sensor

READY

Self priming sensor

LSTS

Staple empty sensor

NCTS

Cartridge empty sensor

STND

Staple supply cover open/close sensor

T2PUD

2nd tray upper surface sensor

3-3

Purpose

Operation test/check

Function
(Purpose)

Used to check the operation of the load in the finisher
and the control circuit.

Section

Sorter/Finisher

Item

Operation

(Initial screen)

(Executing screen)

1:JGM1

Side guide plate drive motor

2:JGM2

Rear edge plate drive motor

3:FM-600

Finisher main motor (600dpi)

4:FM-1200

Finisher main motor (1200dpi)

Disabled

5:EVM

Tray lift-up motor

6:OFM

Tray offset motor

7:STM

Staple operation motor

Sim3-2 SENSOR 1/2

INPD FWPS

JGHP1

JGHP2 JGPD T1OD

T1PF

PGOP

T2OD

OFHP T2UP

T2DN

Sim3-3 OUTPUT CHECK

1:JGM1 4:FM-1200

2:JGM2 5:EVM

3:FM-600 6:OFM

1/3 EXEC

Sim3-3 OUTPUT CHECK

7:STM 10:JGSL1

8:

OGSLR

11:JGSL2

9:OGSLL 12:SHTSL

2/3

EXEC

8