AR-5127 SIMULATION 8 - 34

Operation/procedure
Keep the OC cover open for execution of this test command.
If the adjustment is normally completed, the adjusted value is dis-
played and written into the EEPROM.
If the adjustment is abnormal, "ERR" is displayed and the value is not
written into the EEPROM.
For that which is not adjusted because of abnormality, "---" is dis-
played.

Operation/procedure
Pressing the [OK] key performs the LSU test.
Used to set the LSU to ON state and check that the sync signal
(HSYNC/) is outputted or not.
After operation for 30 sec, the result is displayed. (Interruption cannot
be made for 5 sec after starting the operation.)

Operation/procedure
Pressing the [OK] key performs shading, and displays the result (cen-
ter pixel).

Operation/procedure
Set the SPF unit OPEN, and press the [OK] key.
[ ] indicates the order number of the pixel of the white sheet for SPF
exposure correction in the SPF position.
If the adjustment is normally completed, "COMPLETE" is displayed
and data are written into the EEPROM.
In case of an abnormality, "ERROR" is displayed and no data is written
into the EEPROM.
The SPF white correction start pixel = Displayed pixel position - 34
If the simulation is executed with the SPF unit closed, an error is
resulted.

53

53-8

Purpose

Adjustment

Function
(Purpose)

Used to adjust the mirror unit SPF scan position
automatically.
For the SPF scan position auto adjustment, the mirror
unit is shifted to 11mm before the SPF glass cover
edge and is moved by self-boost, and images are
scanned in each step, and the position from the glass
cover edge is automatically detected.
[Adjustment value]

Default: 50

Setting range: 1 to 99

Adjustment unit 1 = about 0.127mm

(Initial screen)

(Executing screen)

"EXEC" is highlighted during execution.

(Normal end screen)

(Abnormal end display)

61

61-1

Purpose

Operation test/check

Function
(Purpose)

Used to test the operation of the LSU.

Section

LSU

Item

Operation

(Initial screen)

(Executing screen)

Interruption is inhibited
during execution.
During execution,
[EXEC] is highlighted.

(Result screen/Normal) (Result screen/Abnormal)

Sim53-8 SPF AUTO

PRESS OK KEY EXEC

Sim53-8 SPF AUTO

EXEC

Sim53-8 SPF AUTO

SPF STOP ADJ [ 47]

PRESS OK KEY EXEC

Sim53-8 SPF AUTO

SPF STOP ADJ [ERR]

PRESS OK KEY EXEC

Sim61-1 LSU CHECK

PRESS OK KEY EXEC

Sim61-1 LSU CHECK

EXEC

Sim61-1 LSU CHECK

COMPLETE EXEC

Sim61-1 LSU CHECK

ERROR EXEC

63

63-1

Purpose

Adjustment/setting/operation data output/check
(display/print)

Function
(Purpose)

Used to check the result of shading correction. (The
shading correction data are displayed.)

Section

Scanner (Exposure)

Item

Operation

(Initial screen)

(Executing screen)

(Screen after execution
screen)

63-7

Purpose

Adjustment

Function
(Purpose)

Used to adjust the SPF white correction start pixel
position automatically.
This adjustment is performed after the lens unit is
replaced.

Section

Scanner

Item

Operation

(Initial screen)

(Executing screen)

Interruption is inhibited
during execution.
During execution,
[EXEC] is highlighted.

(Initial screen with the execution result displayed)
Normal end screen

Abnormal end screen

Sim63-1 SHADING

PRESS OK KEY

EXEC

Sim63-1 SHADING

EXEC

Sim63-1 SHADING

PRESS OK KEY

EXEC

40

Sim63-7 SPF ADJ.

WHITE ADJUST

PRESS OK KEY

Sim63-7 SPF ADJ.

WHITE ADJUST

EXEC

Sim63-7 SPF ADJ.

WHITE ADJUST

COMPLETE

[160]

PRESS OK KEY EXEC

Sim63-7 SPF ADJ.

WHITE ADJUST

ERROR

[ 0]

PRESS OK KEY EXEC

Advertising