AR-5127 SPECIFICATIONS 3 - 3

(5) Original size/Scanning area

a. Max. original size

b. Scanning area

(6) Scanning speed

(7) Light source (lamp)

(8) Read sensor

D. Scanner (exposure) section

(1) Resolution

(2) Gradation

(3) Laser unit specifications

E. Image process section

F. Fusing

G. Drive

4. Safety and environmental protection

standards

(1) Safety and environmental protection standards

(2) Ozone level

(3) Noise level

5. Environment conditions

(1) Space required

(2) Operating ambient conditions

A3 paper (11" × 17")

122mm/sec (600 dpi: magnification ratio 100%)

Type

Xenon

Drive voltage

1.5 kV

Type

Reduction optical system image sensor (CCD)
Monochrome

Main scanning direction

Sub scanning direction

600 dpi

600 dpi

2 gradations

r.p.m.

28,800 rpm

Mirror surfaces

6 faces

Laser power

0.4mW/600dpi, 0.2mW/1200dpi

Laser beam size

60

µ (

Main scan) x 70

µ

(Sub scan)

Laser wave length

785nm

Imaging speed

600 dpi : 122 mm/sec.

Photo
conductor

Type

OPC drum (dia. 30mm)

LIFE

50,000 sheets

Toner

Type

Developer (Black)

LIFE

33,000 sheets (Toner, life: 33k, Developer life:
50k)

Charge

System

(–) DC scorotron (saw tooth)

Voltage

560

µ

A constant electric current

Transfer

System

Transfer roller

Voltage

18

µ

A (electric current)

Exposure

Xenon lamp

Developing

Dry, 2-component magnetic brush
development

Separation

(–) DC corotron

Discharge

Cleaning

Blade

356 mm

CENTER

216 mm

Type

Heat roller

Lamp

Type

Halogen lamp

Voltage

100V

Power
consumption

1000W

Fusing temperature

185° (600 dpi)
160° (1200 dpi)

Heat roller

Teflon coated roller

Pressure roller

Silicone rubber roller with roentgerized
cube

Separation system

Natural separation (with pawl)

Drive section

Motor

Main motor

DC brushless motor

Item

Standard name

Country name

Safety
standards

S mark

Japan

SEMKO mark

EU

Radio wave
noise standard

CE mark

EU

EnergyStar

World-wide

Ozone

Less than 0.02mg/m³

Dust

Less than 0.075mg/m³

Operating

Less than 63dB

On standby

Less than 40dB

Folded multi manual feed

623 (W) × 585.5 (D) mm

Open multi manual feed

889 (W) × 585.5 (D) mm

Temperature (˚C)

Humidity (%)

Advertising