AR-5127 SIMULATION 8 - 37

• The make time set in the dial test is written into the corresponding

soft SW.

• Default: 1 2 3 4 5 6 7 8 9 0

Operate the [

] [

] key in DP dial selection menu to switch. (Time

before pulse delivery can be changed as 2sec

4sec

8sec.)

• Set the signal send level to 0dB or the soft SW set value.

Used to set the high level group and the low level group of DTMF
signal send level. By executing the test, DTMF signal is sent from
the line to a recorded dial number of max. 100 digits.

• The high group/low group value of the DTMF signal send level set in

the dial test is written into the corresponding soft SW.

• Default: 1 2 3 4 5 6 7 8 9 * 0 #

In the PB dial select menu, press [

][

] keys to select.

Pressing the [CLEAR] key during the operation clears the input
value and returns to the value input menu.

• Max. 100 digits can be assigned to each dial (0 - 9, *, #). While the

default value is displayed at first, a desired value can be entered and
the entered value is stored on the FAX side until the menu is can-
celed.

• After completion of the mode, the signal send level is returned to the

soft SW set value before execution of the mode.

Note: Executable only when the FAX is installed.

Operation/procedure
Set the signal send level to 0dB or the soft SW set value, and specify
one dial to be delivered to.
The DTMF signal of the specified dial number is delivered until the
interruption command is provided by pressing the [BACK] key.) When
another dial number is specified during delivery of the signal, the new
dial number is delivered.
The signal send level is returned to the soft SW set value before exe-
cution of the mode after completion of the mode.
Note: Executable only when the FAX is installed.

Operation/procedure
The following FAX information is printed.

Note: Executable only when the FAX is installed.

Operation/procedure
When the relay state of the polarity reverse relay, the handset hook
switch, or the external telephone hook switch is changed, the content
of change is displayed regardless of the soft SW setup. The display of
change is kept until an interruption command is supplied by pressing
the [BACK] key.

Note: Executable only when the FAX is installed.

Operation/procedure
The data received from the line are checked to insure that the following
reception data are identical to the judgment data. If identical, "OK" is
notified. If not, "NG."
A judgment is made according to the reception start data. Continuous
coincidence is required.

Note: Executable only when the FAX is installed.

Operation/procedure
The send/receive test is performed, and the time required for send/
receive of the image data in the test is measured and displayed.

3. DTMF signal send test

Make time

1ms for input value of 1. Adjust so that the dial pulse
make rate is within 33±3%. (For North America,
40±3%.)
Dial pulse make rate =

Make time / (Make time + Break time)

Break time

It is obtained from the formula below and
automatically set.
PPS = 1000 / (make time + break time)

DTMF signal
adjustment

The signal send levels are classified into the high
group and the low group. The send level is 0.5dB for
each 1 of input value.

66-17

Purpose

Adjustment/Setting/Check

Function
(Purpose)

DTMF signal send

Related soft SW SW53-1 to 4 (DTMF high group end level)

SW53-5 to 8 (DTMF low group send level)

66-21

Purpose

Adjustment/Setting/Check

Function
(Purpose)

FAX information print

Print information

Details

A

User switch list

B

Soft SW list

C

Dump list

D

System error

Used to print the system error log (error
number and time). For this operation, the
system error log is always stored as the
ring buffer in the SRAM 256byte area.

E

Protocol monitor

Regardless of soft SW19-1 status, the
protocol monitor of the preceding
communication is printed. (Printing is
allowed at any time before starting the
next communication.) For this operation,
the protocol monitor of one
communication is always buffered.

66-30

Purpose

Adjustment/Setting/Check

Function
(Purpose)

Recognize TEL/LIU state change.

Check signal

Notification contents

Signal low

Signal high

HS2

ON

OFF

HS1

ON

OFF

RHS

ON

OFF

EXHS

ON

OFF

66-32

Purpose

Adjustment/Setting/Check

Function
(Purpose)

Receive data check

Receive speed

300bps

Receive data

00

Number of judgment data

100

66-34

Purpose

Adjustment/Setting/Check

Function
(Purpose)

Communication time measurement display

Related soft SW

SW10-1

Setup on the user
side when executing
communication

Communication
means
Picture quality
Density
ECM
Sender information

: Memory send
: Normal Character
: Lighter
: ON
: OFF

Measuring
range

Send

From flag reception before sending of
image data until sending of RCP frame

Receive

From flag reception before reception of
image data until reception of RCP frame

Mode when measuring

Used to make communication not in a
simulation process but in the normal screen
and measure the time.

Print information

Details

Advertising