AR-5127 SIMULATION 8 - 25

Operation/procedure
The operation status of the sensors and detectors in the original size
detection section are displayed. The active sensors and detectors are
highlighted.

For AB series, PD1 - 5 is displayed, for inch series, PD1 - 4.

Operation/procedure
Place an A3 (or WLT) document on the document table, and press
[OK] key with the OC cover open.
The adjustment is performed and the result is displayed.

The value in [ ] shows the threshold value.
For AB series, 1 - 5 is displayed, for inch series, 1 - 4.
During execution, [EXEC] is highlighted.

Operation/procedure
The detection output level of each sensor is displayed in real time.

The value in [ ] shows the threshold value of 20 degree detection
adjustment.
For AB series, 1 - 5 is displayed, for inch series, PD1 - 4.

Operation/procedure
Set the OC cover at 20 degrees detection and press the [OK] key.

The detection output level of each sensor is displayed in real time.

The value in [ ] shows the threshold value of 20 degree detection
adjustment.
For AB series, 1 - 5 is displayed, for inch series, 1 - 4.
During execution, [EXEC] is highlighted.

Operation/procedure
After the mode selection, enter the adjustment value and press the
[OK] key.

Operation/procedure
Input the set value with the 10-key and press the [OK] key.

OCSW

Original cover state
Open: Highlighted
display
Close: Normal display

PD1 to 5 Original sensor status

Without original:
Normal display
With original:
Highlighted display

41-2

Purpose

Adjustment

Function
(Purpose)

Used to adjust the detection level of the document size
photo sensor.

Section

Others

Item

Operation

(Initial screen)

(Executing screen)

OCSW Original cover state

Open: Highlighted display
Close: Normal display

1 to 5

PD sensor detection
level

41-3

Purpose

Operation test/check

Function
(Purpose)

Used to check the light reception level and the
detection level of the original size detection photo
sensor.

Section

Others

Item

Operation

OCSW Original cover state

Open: Highlighted display
Close: Normal display

1 to 5

PD sensor detection
level

Sim41-1 PD SENSOR

OCSW

PD1 PD2

PD3 PD4 PD5

Sim41-2 PD SENSOR

PRESS OK KEY EXEC

41-4

Purpose

Adjustment

Function
(Purpose)

Used to adjust the detection level of OC 20 degrees.

Section

Others

Item

Operation

(Initial screen)

(Executing screen)

OCSW

Original cover state
Open: Highlighted
display
Close: Normal display

1 to 5

PD sensor
detection level

43

43-1

Purpose

Setting

Function
(Purpose)

Used to set the fusing temperature in each operation
mode.

Section

Fixing (Fusing)

Item

Operation

(Initial screen)

(Input screen)

Display items

Content

Setting range

Default

1:600dpi

600dpi

155-190

185

2:1200dpi

1200dpi

140-190

Disabled

3:POST CARD

Postcard

155-190

185

43-10

Purpose

Setting

Function
(Purpose)

Used to set the paper feed cycle for postcard.

Section

Paper feed

Item

Operation

Setting range

1-99

Default

50

Sim41-4 20˚ SENSOR

PRESS OK KEY EXEC

Sim43-1 FUSER TEMP.

1:600dpi 185

2:1200dpi 160

3:POST CARD 185

2

Sim43-1 FUSER TEMP.

2:1200dpi 160

[140-190]

160

Sim43-10 POST CARD

PICK UP CYCLE 50

[ 1- 99]

50