Sharp Digital Laser Copier/Printer AR-5127 User Manual

Page 38

Advertising
background image

AR-5127 SIMULATION 8 - 10

*1. The negative value of the set value corresponds to the grid high

output voltage.

*2. The set values can be selected from the above 8 patterns only.
*3. The selected pattern determines the grid high voltage and the grid

low voltage.
If, for example, the grid high voltage is set to –480V (pattern 1), the
grid low voltage is –350V.

Operation/procedure
After selecting the mode, enter the adjustment value and press the
[OK] key, and output will be made for 30sec.
The input value is in the increment of –25V.

(

) Linked with the destinations of SIM 26-6.

Linked with the auto exposure mode of SIM 46-19-1.

* SUPER PHOTO (5:) cannot be executed.

When [OK] or [START] key is pressed, a caution buzzer sounds.
(Only the adjustment value can be entered.)

*1. The negative value of the set value corresponds to the grid high

output voltage.

*2. The set values can be selected from the above 8 patterns only.
*3. The selected pattern determines the grid high voltage and the grid

low voltage.
If, for example, the grid high voltage is set to –480V (pattern 1), the
grid low voltage is –350V.

Operation/procedure
After selecting the mode, enter the adjustment value and press the
[OK] key, and output will be made for 30sec.

The minimum increment is 2V.
The result of (Set value – 199) / 2 is stored in the EEPROM.
When reading a value from the EEPROM, the value of (EEP value *2)
+ 200 is used as the set value.
Therefore, the set value entered must be an even number. If an odd
number is entered the entered odd number + 1 is displayed after
pressing [OK] key.

Operation/procedure
After selecting the mode, enter the adjustment value and press the
[OK] key, and output will be made for 30sec.
The input value is in the increment of –25V.

NO.

Set value

Grid High

Grid Low

1 480

–480V

–350V

2 505

–505V

–375V

3

530

–530V

–400V

4

555

–555V

–425V

5

580

–580V

–450V

6 605

–605V

–475V

7 630

–630V

–500V

8 655 –655V

–525V

8-3

Purpose

Adjustment/Operation test/check

Function
(Purpose)

Used to check and adjust the operation of the main
charger grid voltage (low mode) in each copy mode
and the control circuit.

Section

Image process (Photoconductor/Developing/Transfer/
Cleaning)
Photo conductor

(Initial screen)

(Input/Selection screen) (Executing screen)

Display items

Content

Setting

range

Default

1:AE

AE (

)

1-8

3 (–400V)

2:TEXT

Character

5 (–450V)

3:TEXT/PHOTO

Character/Photo

5 (–450V)

4:PHOTO

Photo

5 (–450V)

5:SUPER PHOTO *

Super photo

Disabled

6:TONER SAVE

Toner save

2 (–375V)

NO.

Set value

Grid High

Grid Low

1 480

–480V

–350V

2 505

–505V

–375V

3

530

–530V

–400V

4

555

–555V

–425V

5

580

–580V

–450V

6 605

–605V

–475V

7 630

–630V

–500V

8 655 –655V

–525V

Sim8-3 MHV(L) COPY

1:AE 3

2:TEXT 5

3:TEXT/PHOTO 5

1/2

Sim8-3 MHV(L) COPY

5:SUPER PHOTO 3

EXEC [ 1- 8]

3

Sim8-3 MHV(L) COPY

5:SUPER PHOTO 3

EXEC

[ 1- 8]

3

8-10

Purpose

Adjustment/Operation test/check

Function
(Purpose)

Used to check and adjust the operation of the
developing bias voltage in each printer mode and the
control circuit.

Section

Image process (Photoconductor/Developing/Transfer/
Cleaning)
Developer/Toner hopper

(Initial screen)

(Input/Selection screen) (Executing screen)

Display items

Content

Installation

range

Default

1:DENS1(600)

Density 1 (600dpi)

200-550

400 (–400V)

2:DENS2(600)

Density 2 (600dpi)

450 (–450V)

3:DENS3(600)

Density 3 (600dpi)

450 (–450V)

4:DENS4(600)

Density 4 (600dpi)

450 (–450V)

5:DENS5(600)

Density 5 (600dpi)

500 (–500V)

6:TS(600)

Toner save (600dpi)

350 (–350V)

7:DENS1(1200)

Density 1 (1200dpi)

Disabled

8:DENS2(1200)

Density 2 (1200dpi)

Disabled

9:DENS3(1200)

Density 3 (1200dpi)

Disabled

10:DENS4(1200)

Density 4 (1200dpi)

Disabled

11:DENS5(1200)

Density 5 (1200dpi)

Disabled

8-11

Purpose

Adjustment/Operation test/check

Function
(Purpose)

Used to check and adjust the operation of the main
charger grid voltage (high mode) in each printer mode
and the control circuit.

Section

Image process (Photoconductor/Developing/Transfer/
Cleaning)
Photo conductor

(Initial screen)

(Input/Selection screen) (Executing screen)

Sim8-10 DV BIAS PRT

1:DENS1(600) 400

2:DENS2(600) 450

3:DENS3(600) 450

1/4

Sim8-10 DV BIAS PRT

5:DENS5(600) 500

EXEC [200-550]

500

Sim8-10 DV BIAS PRT

5:DENS5(600) 500

EXEC

[200-550]

500

Sim8-11 MHV(H) PRT

1:DENS1(600) 3

2:DENS2(600) 5

3:DENS3(600) 5

1/4

Sim8-11 MHV(H) PRT

5:DENS5(600) 7

EXEC [ 1- 8]

7

Sim8-11 MHV(H) PRT

5:DENS5(600) 7

EXEC

[ 1- 8]

7