Sharp Digital Laser Copier/Printer AR-5127 User Manual

Page 40

Advertising
background image

AR-5127 SIMULATION 8 - 12

*1. The negative value of the set value corresponds to the grid high

output voltage.

*2. The set values can be selected from the above 8 patterns only.
*3. The selected pattern determines the grid high voltage and the grid

low voltage.
If, for example, the grid high voltage is set to –480V (pattern 1), the
grid low voltage is –350V.

Operation/procedure
Enter the adjustment value and press the [OK] key, and output opera-
tion is performed for 30sec.

*1. The negative value of the set value corresponds to the grid high

output voltage.

*2. The set values can be selected from the above 8 patterns only.
*3. The selected pattern determines the grid high voltage and the grid

low voltage.
If, for example, the grid high voltage is set to –480V (pattern 1), the
grid low voltage is –350V.

Operation/procedure
Select with the 10-key and operate for 30 seconds.

Operation/procedure
Set the rotation speed of the duplex motor.

Operation/procedure
Set the switch back time of the duplex motor.

Operation/procedure
Press the [OK] key and operate the toner motor for 30 sec.
Pressing the [INTERRUPT] key interrupts the operation, and the dis-
play returns to the main code entry screen.

NO.

Set value

Grid High

Grid Low

1 480

–480V

–350V

2 505

–505V

–375V

3

530

–530V

–400V

4

555

–555V

–425V

5

580

–580V

–450V

6 605

–605V

–475V

7 630

–630V

–500V

8 655 –655V

–525V

8-15

Purpose

Adjustment/Operation test/check

Function
(Purpose)

Used to check and adjust the operation of the main
charger grid voltage (low mode) in FAX mode and the
control circuit.

Section

Image process (Photoconductor/Developing/Transfer/
Cleaning)
Photo conductor

(Initial screen)

(Executing screen)

Setting range

1-8

Default

5

NO.

Set value

Grid High

Grid Low

1 480

–480V

–350V

2 505

–505V

–375V

3

530

–530V

–400V

4

555

–555V

–425V

5

580

–580V

–450V

6 605

–605V

–475V

7 630

–630V

–500V

8 655 –655V

–525V

9

9-1

Purpose

Operation test/check

Function
(Purpose)

Used to check and adjust the operation of the load
(motor) in the duplex section and the control circuit.

Section

Duplex

Item

Operation

Sim8-15 MHV(L) FAX

FAX 5

EXEC [ 1- 8]

5

Sim8-15 MHV(L) FAX

FAX 5

EXEC

[ 1- 8]

5

(Initial screen)

(Executing screen)

1:DMF600

Duplex motor forward rotation (600dpi)

2:DMF1200

Duplex motor forward rotation (1200dpi)

Disabled

3:DMR600

Duplex motor reverse rotation (600dpi)

4:DMR1200

Duplex motor reverse rotation (1200dpi)

Disabled

9-4

Purpose

Operation test/check

Function
(Purpose)

Used to adjust the rotation speed of the duplex motor.

Section

Duplex

Item

Operation

Setting range 1-13
Default

3

9-5

Purpose

Adjustment

Function
(Purpose)

Used to adjust the switch back time of the duplex
motor.

(Initial screen)

(Input screen)

Display items

Installation range

Default

1:600dpi

18-76

50

2:1200dpi

Disabled

10

10-0

Purpose

Operation test/check

Function
(Purpose)

Used to check the operation of the toner motor and its
control circuit.

Section

Image process (Photoconductor/Developing/Transfer/
Cleaning)
Developer/Toner hopper

Item

Operation

Sim9-1 MOTOR CHECK

1:DMF600 4:DMR1200

2:DMF1200

3:DMR600

EXEC

2

Sim9-1 MOTOR CHECK

1:DMF600 4:DMR1200

2:

DMF1200

3:DMR600

EXEC

2

Sim9-4 MOTOR SPEED

MOTOR SPEED 3

[ 1- 13]

3

Sim9-5 SW BACK TIME

1:600dpi 50

2:1200dpi 50

1

Sim9-5 SW BACK TIME

1:600dpi 50

[ 18- 76]

50