Siemens 500 NIM User Manual

Page 80

Advertising
background image

NIM Primitives

4-27

SIMATIC TIWAY I Series 500 NIM User Manual

Table 4-7

Maximum Write Primitive Byte Length

Write Primitive

Maximum number of
written per Primitive

(When using extended

address)

30

267

265

31

265*

263*

52

263

261

57

265**

263**

bytes that may be
request.

* This number assumes that only one data element is requested. Use the

one of the following formulas for the general case of one or more

where:

N = maximum number of bytes which may be written in this

Primitive request.

T = total number of writes specified in the Primitive request.

** This number assumes that only one record is requested. Use the formula

below for the general case of one or more records requested:

N = 266 - C, where: C = total number of records in this Primitive.

or

Extended addressing: N = 264 - C

Consult

for the maximum available data element address.

data types:

Normal addressing: N = 270 - (5 * T)

Extended addressing: N = 270 - (7 * T)

for the number of bytes in each data element, and

Table 4-4

Table 4-5

Advertising