Interface specifications 1, Commands (rs-485 only) – Sanyo DSR - 300 User Manual

Page 87

Advertising
background image

INTERFACE SPECIFICATIONS

1

86

English

(when optional interface board is installed)

INTERFA

C

E

S

P

E

C

IFICATIONS

„

GROUP SET (6CH)

z

Sent when grouping (appending group numbers).
Send the 2-byte group number after confirming the
ACK (0AH) signal has been sent from the recorder.

Example: Setting group number 5

„

GROUP CHECK (6DH)

z

Returns the group number.

Example: Group number 2

„

GROUP CLEAR (6EH)

z

Clears the group number. Send the 2-byte group
number after confirming the ACK (0AH) signal has
been sent from the recorder.

Example: Group number 8

„

STATUS LOG 1 (BFH)

z

A header containing mode change information,
returned from the recorder to the system controller
when the recorder is operated with the RS-485
interface in use. (JP. 87)

„

MENU UPLOAD (D8H)

z

Sends the recorder’s menu settings to the controller
(and saves them in the controller).

„

MENU DOWNLOAD (E8H)

z

Sends the menu settings saved in the controller to
the recorder, replacing the existing settings.

„

CLOCK DOWNLOAD (E9H)

z

Sets the time in the recorder, with time information
from the controller.

„

RS-485 SEND START (FDH)

z

Sent before the command is sent. Waits for ACK
(0AH) confirmation.

„

RS-485 RCV CMF (FEH)

z

Sent after receiving a command. Waits for RS-485
SEND START (FDH).

Commands (RS-485 only)

RXD

TXD

0A

00

0A

20

0A

6C

RXD

TXD

00

04

6D

RXD

TXD

0A

01

0A

00

0A

6E

RXD

TXD

40

0A

D8

RXD

TXD

40

0A

0A

0A

0A

E8

RXD

TXD

40

E9

e00_l8had_us_7.book Page 86 Wednesday, March 10, 2004 2:47 PM