Installing the Bridge Hardware

24

2.9

Periodic Maintenance

Periodic maintenance consists of cleaning of the bridge’s two internal air filters.

This should be done at least once per year, and more often as required by the

bridge’s environment.

Figure 12 Location of Air Filters

Air Filter

(behind Vent)

Air Filter

(behind Vent)

Upper

Lower

Remove 2 screws,

remove power supply

to clean

Lower Filter

Cleaning the Filters

You will have to remove operating power to the bridge before cleaning the filters.

Contact your network administrator and make sure your application will not be

adversely affected. Then remove power to the bridge.

Remove the filters, clean them with a detergent solution suitable for your site, and

reinstall them. The filter locations are described below.

Upper Filter

Remove the four screws securing the bridge’s enclosure cover, and remove the

cover. The upper filter is accessible behind the bridge’s front panel.

Lower Filter

Remove the two screws securing the bridge’s power supply, and move the supply

away from the rest of the bridge assembly. The lower filter is accessible behind

the power supply’s front panel.