Diagnostic Tools

63

If you enter a routing path of 22.00.00.00, you are instructing the program to

analyze a second network that is connected to the remote side of a Bridge Plus

device, whose address is 22 on the local network.

If you enter 22.24.00.00, you are instructing the program to analyze a third

network that is connected through two Bridge Plus devices ---- through address 22

on the local network, and then through address 24 on the second network.

While running MBPSTAT, you can change the routing path to select another

network through an option on your program menu.

Figure 20 Typical MBPSTAT Routing

MBPSTAT

Routing

22

24

Local Network

Second Network

Third Network

00 00 00 00

22 00 00 00

22 24 00 00

Bridge

Running

MBPSTAT