Configuring the Bridge
30
3.4
Configuration With the CFGUTIL Utility
If a BOOTP server is not available, you can configure the bridge locally using its
internal CFGUTIL.EXE utility.
Set the bridge power switch to 0 (OFF). Refer to the connector panel detail in
Figure 8 and connect a keyboard and VGA monitor to the bridge. Then set the
bridge power to 1 (ON).
3.4.1
Starting CFGUTIL
Press Ctrl--C to stop the bridge application. This will display the bridge’s
command line prompt. Enter CFGUTIL to start the utility.
Here is an example of the opening menu in CFGUTIL.
Figure 14 CFGUTIL Opening Menu
3.4.2
Navigating the CFGUTIL Menu
Use your Tab key, or Shift and Tab, to select a field for editing. F2 displays Help.
Note the six configuration fields at the left side of the menu. You should configure
these fields first, before setting up the MB+ and TCP mapping fields. Refer to
Sections 3.4.3 and 3.4.4 for details.