5-15

Overheat/Fan Fail LED

Connect an LED to the OH/Fan Fail

connection on pins 7 and 8 of JF1

t o p r o v i d e w a r n i n g o f s y s t e m

overheating or system fan failure.

The LED will flash/stay on as long

as the fan fail/overheat condition

exists. Refer to the table on the

right for pin definitions and Chap-

ter 3 for details.

NIC1/2 LEDs

The NIC (Network Interface Con-

t r o l l e r ) L E D c o n n e c t i o n s f o r

GLAN1 are located on pins 11 and

12 of JF1 and the NIC LED con-

nections for GLAN2 are located on

pins 9 and 10 of JF1. Attach the

NIC cables to display network ac-

tivity. Refer to the table on the

right for pin definitions.

NIC LED

Pin Definitions

(JF1)

Pin

Number

9/11

10/12

Definition

Vcc

GND

OH/Fan Fail LED

Pin Definitions

(JF1)

Pin

Number

7
8

Definition

Vcc

GND

Power/Power Fail

LED Pin Definitions

(JF1)

Pin

Number

5
6

Definition

LED-

LED+

HDD LED

The HDD LED (for IDE and SCSI

drives) connection is located on

pins 13 and 14 of JF1. Attach the

drive LED cable to these pins to

display disk activity. See the table

on the right for pin definitions.

HDD LED

Pin Definitions

(JF1)

Pin

Number

13
14

Definition

Vcc

HD Active

Power & PWR Fail LED

The Power/Power Fail LED con-

nection is located on pins 5 and 6

of JF1. Refer to the table on the

right for pin definitions.