1 before you begin, 2 what to do, Before you begin – Sun Microsystems Sun Fire X4200 User Manual

Page 115: What to do

Advertising
background image

Chapter 9

System Monitoring and Maintenance Using the SP GUI

9-9

Upper critical – 35 degrees C

Upper non-recoverable – 40 degrees C

CPU 0 (p0.t_core) and CPU 1 (p1.t_core) die temperatures

Upper non-critical – 55 degrees C

Upper critical – 65 degrees C

Upper non-recoverable – 75 degrees C

There are three other temperature sensors:

I/O board ambient temperature (io.t_amb)

Motherboard ambient temperature (mb.t_amb)

Power distribution board ambient temperature (pdb.t_amb)

9.5.1

Before You Begin

Log in to the service processor (SP) as Administrator or Operator to reach the ILOM
web GUI.

9.5.2

What to Do

1. From the System Monitoring tab, choose Sensor Readings.

The Sensor Readings page appears.