Sat measurement – Kathrein MSK 25 User Manual

Page 21

Advertising
background image

SAT measurement

21

Bearing for Individual Reception Frequencies

The „LEVEL ♫“ function allows the antenna alignment to maximum
received signal via bearing. The level tendency can be bargraph-
displayed.The measurement range can be adjusted to three different
sensitivity levels.

The level can be monitored with an acoustic signal, the pitch of which is
proportional to the received-signal level. The volume of the directional
radio audio signal can be adjusted with the volume regulator.

Bearing Menu

[2ndF] [LEVEL ♫] Changing over to bearing mode:

[-] [+] Change-over of the measurement range of the bar graph. The
measurement range is automatically preselected.

Level range 1: high input levels

Level range 2: medium input levels

Level range 3: low input levels

[2ndF] [2ndF] Exit

LC display:

• Level range 2: medium input level
• Mode: SAT
• Bargraph display


Example

Calling up „LEVEL ♫“ mode

Press [2ndF] [LEVEL♫].

Move the antenna until the maximum amplitude of the bargraph display is
reached.

If necessary, diminish or elevate the sensitivity by pressing either [-] or
[+] .

Repeat this procedure until the maximum level is reached.

Exit:

Press [2ndF] twice.



LEV-Range:2

SAT

> ■■■■