Sat measurement – Kathrein MSK 25 User Manual

Page 29

Advertising
background image

SAT measurement

29

Command Byte Menu

MSK 25 can send commands under DiSEqC™ 1.0 but cannot receive
them. All the commands requiring DiSEqC™ 2.0 (sending and receiving)
are underlined grey in the table below.

Commands in bold are particularly preferred for KATHREIN switching
matrices.

Hex Byte

Command

Description

Numbe

r of

data

bytes

00

Reset

Reset DiSEqC™ Microcontroller

-

01

Clr Reset

Delete reset flag

-

02

Stand-by

Switching off peripheral power supply unit

-

03

Power on

Switching on peripheral power supply unit

-

04

Set Contend

Adjustment of contention flag

-

05

Contend

Feedback only if contention flag has been set

-

06

Clr Contend

Delete contention flag

-

07

Adresse

Feedback only if contention flag has not been set

-

08

Move C

Change address when contention flag has been set

1

09

Move

Change address when contention flag has not been set

1

10

Status

Read status register flags

-

11

Config

Read configuration flags

-

14

Switch 0

Read switching status flags (Committed Port)

-

15

Switch 1

Read switching state flags (Uncommitted Port)

-

16

Switch 2

Expansion option

-

17

Switch 3

Expansion option

-

20

Set LO

Calling up of low local oscillator frequency

-

21

Set VR

Calling up the vertical polarisation or clockwise circular
polarisation

-

22

Set Pos A

Select satellite position A

-

23

Set S0A

Select switchoption A

-

24

Set Hi

Calling up of high local oscillator frequency

-

25

Set HL

Calling up of horizontal polarisation or counter-clockwise
circular polarisation

-

26

Set Pos B

Select Satellitenposition B

-

27

Set S0B

Select switchoption B

-

28

Set S1A

Calling up of matrix S1 input A (input B inactive)

-

29

Set S2A

Calling up of matrix S2 input A (input B inactive)

-

2A

Set S3A

Calling up of matrix S3 input A (input B inactive)

-

2B

Set S4A

Calling up of matrix S4 input A (input B inactive)

-

2C

Set S1B

Calling up of matrix S1 input B (input A inactive)

-

2D

Set S2B

Calling up of matrix S2 input B (input A inactive)

-

2E

Set S3B

Calling up of matrix S3 input B (input A inactive)

-

2F

Set S4B

Calling up of matrix S4 input B (Eingang A inactive)

-

30

Sleep

All bus commands ignored, except „Awake“

-

31

Awake

Bus commands again accepted

-

38

Write N0

Setting Port Group 0

1

39

Write N1

Setting Port Group 1

1

3A

Write N2

Expansion option

1

3B

Write N3

Expansion option

1

40

Read A0

Read analogue value A0

-

41

Read A1

Read analogue value A1

-

48

Write A0

Set analogue value A0

1

49

Write A1

Set analogue value A1

1

А

Advertising